Technical Specifications
Model
E² 1050 IB
Input
Range / Frequency(50Hz±5%)
145~300V AC
Output
Voltage / Transfer Time
230V ± 9% AC / <6ms
Regulator on Mains / Regulator on Battery
Automatic Voltage Regulation / Pulse Width Modulation
Protection
Unit Input / Noise
Fuse Protection / Noise Filter
Short Circuit (Line) / Short Circuit (Inverter)
Fuse Protection / Pulse to Pulse Electronic active Protection
Battery
Type / Recharge Time
SMF / 2~5 Hrs. (depending on the status of Battery)
Backup Time/ Batery Rating
10 ~20mins. (Load 2PC) / 12V 7.2AH x 2
Alarm
Battery Backup (Sound beeping)
1 Beep Per 10 sec. (Approx.)
Low Battery
2 Beep Per 2 sec. (Approx.)
No Load
1 Beep Per 2 sec. (Approx.)
Short Circuit / Overload
Sound Beeping Continuously / Rapid
LED Display
Green
Mains mode operation / AVR Working
Red / Orange
Inverter output from battery
Physical
Size (L x W x H)
(350x125x170)mm
Weight (Approx.):
11Kg.
Environment
Operating Temperature / Rel. Humidity
0ºC ~ 48ºC ; 32ºF ~ 120ºF / 0 to 90% non-condensing
Noise
Audible Noise level
<35dB, distance 1 meter from UPS

* Above specifications are measured under computer load.