UPS Hybrid HB 1650VA

none
none

UPS Hybrid HB 1650VA

  • Battery : 2 Battery System
  • Waveform : SINEWAVE
  • Input AC Range : Wide : 100V~300V AC, Standard : 180V~260V AC
  • Input DC Range : 21 ~ 28.4
  • Efficiency (on battery mode) : >80%
  • Protection : Overload : 110%, Short - Circuit : 300%
  • Charger Current : 14A ± 1A
  • Features
  • Specifications
  • Request for Home Delivery

MICRO CONTROLLER/DSC BASED Gen-Next UPS 24X7are based on Hybrid Technology which is a combination of Digital and Sinewave Technologies for Better Performance and High Reliability. The Hybrid Technology used ensures noiseless performance, Quick Charging, More Load, Longer Battery Life and Longer Backups.
Hybrid Technology for Noiseless and Better Performance. You get longer backups & increased life of battery.
Battery type (Branded/Local/Tubular) selection mode switch, suitable to work with equal performance with all type of available batteries.
Charging current selection switch for Standard (10MP) & Fast Charging (14MP), which keeps the battery ready for frequent emergencies.
IBGM Technology - Increases Battery Life and Performance by maintaining correct battery gravity.
Unique USS (Ultra Sonic Switching) - This technology ensures absolute Silent Operations to give you complete peace of mind.
Pure and stable Sinewave Output with very Low THD, under all battery and load conditions.
Digital Signal Controller (DSC) Based Intelligent Control Hybrid Design
PWM Controlled multistage ATM (Automatic Trickle Mode) Charging
Display Indications (Status & Fault)
Smart Overload Sense and Short Circuit Protection
Easily Serviceable
Auto Reset Feature
In-built Bypass Switch - This additional bypass switch enables you to isolate your UPS from mains, whwnever needed.
Slide switch to select float charging voltage
Mains Input Voltage Range Selection
Quick Charging Option

Technical Specifications
Input Voltage
(Standard Range)
 (Narrow Range)
:
100V~300V
180V~260V
Output Voltage on Mains Mode
:
Same as Input
Output Voltage on UPS Mode
:
210V ± 10%
Output frequency on UPS Mode
:
50 Hz ± 0.1 Hz
Switching from Mains to UPS
and from UPS to Mains
:
Automatic
Output Waveform on Mains Mode
:
Same as Input
Battery Charging Current
:
Constant Charging Approx 10% of The Rated Battery Current in AH
Charger
:
Power Factor Controlled Boost Technology
Efficiency
:
> 80%
UPS Overload / UPS Short Circuit
:
110% / 300%
UPS Transfer Time
:
≤ 15 msec.
Technology
:
Digital Signal Controller (DSC) Based Intelligent Control Hybrid Design
Auto Reset Feature
:
Yes
NOTE : Because of a policy of continuous product improvement, the specifications are subject to change without notice.

Your Name*

Your Street Address*

Your City*

Your State*

Your Pin Code*

Your Contact Number*

Your Email Id*

Product You want to buy*

Model Number of the product*

Quantity*

Security Captcha - Type the Letters in the image below

captcha
Any Additional Information

May, 06, 2015

0

SHARE THIS